Text Material Preview
Explanation: For conducting short circuit test, l.v. winding is short circuited and it is not performed at rated voltage. 13. Transformers with high leakage impedance is used in a) arc welding b) power distribution c) power generating terminals d) none of the mentioned View Answer Answer: a Explanation: The feature of the high impedance is extracted in the arc welding applications. 14. Which of the following conditions have to ensured for a open-circuit test? A. Performed on L.V side B. Leakage impedance can be obtained C. It is performed at rated voltage D. It gives magnetizing impedance a) B,D b) A,B,C c) B,C,D d) A,C,D View Answer Answer: d Explanation: Leakage impedance is not found from open-circuit test. 15. Which of the following conditions have to ensured for a open-circuit test? A. Performed on L.V side B. Leakage impedance can be obtained C. It is performed at 10-12% of rated voltage D. It gives magnetizing impedance a) B,D b) A,B,C c) B,C,D d) A,D View Answer Answer: a Explanation: Leakage impedance is not found from open-circuit test. And it is performed on the rated voltage to account for core losses. 16. Which of the following informations are not obtained from short-circuit test? I. Ohmic losses at rated current II. Equivalent resistance and leakage reactance III. Core losses IV. Voltage regulation a) I,II b) II,III c) I,II,IV