Prévia do material em texto
1 / 5 Exam : NS0-015 Title : https://www.passcert.com/NS0-015.html 1.Which two configuration steps are essential when installing MetroClusterTiebreaker software? (Choose NetApp Implementation Engineer – MetroCluster Exam 2 / 5 two.) A. Configure SyncMirror B. Upgrade ONTAP C. Set up IP connectivity between clusters D. Install and configure Tiebreaker host with required credentials Answer: CD 2.What are two key prerequisites for deploying a MetroCluster solution (IP or FC)? (Choose two.) A. Switching infrastructure (FC or IP) B. Ethernet cables C. WAN redundancy D. USB connectivity Answer: AC 3.Which tool confirms compatibility between a fabric-attached MetroCluster ONTAP software release and an FC switch firmware release? A. Active IQ Config Advisor B. ONTAP Mediator C. MetroCluster Tiebreaker software D. Active IQ Unified Manager Answer: A 4.A financial-services firm reports that several mirrored aggregates across multiple nodes in one site all dropped to a degraded state at nearly the same moment, while the local disk pools at that site show their disks as healthy. The engineer suspects a shared back-end fabric fault rather than a disk problem. Which two observations would best support isolating the cause to the back-end fabric (bridges/switches/ISL) rather than to storage media? (Choose two.) A. The degraded aggregates all lost the remote plex crossing the fabric, while the local plex stayed online B. The connectivity/interconnect health-check component reports errors on the bridges or switch ports carrying mirror traffic C. The affected disks report imminent-failure SMART health warnings across every local disk pool feeding those degraded mirrored aggregates at the site D. SnapMirror relationships on the same nodes show steadily increasing replication lag over the same time window E. The Mediator reports it has lost its configured witness IP address at the third-site location Answer: AB 5.A MetroCluster IP configuration has a witness deployed to arbitrate failures. A complete site outage occurs at one location while the inter-site links are also lost. How does the witness allow the surviving site to proceed without risking split-brain? A. The witness merges the two sites' write logs after the fact so both can keep serving during the outage B. The witness stores a third synchronous plex copy of the data that the survivor mounts during the outage 3 / 5 C. The witness forces both sites to halt until an administrator manually chooses which survivor to bring online, preventing any automatic switchover from proceeding on its own D. The witness independently confirms the peer is truly down, authorizing an AUSO at the survivor and barring the isolated site from serving the same data Answer: D 6.A global enterprise is evaluating MetroCluster FC versus MetroCluster IP for mission-critical workloads across two data centers, requiring zero data loss (RPO=0), automated switchover, predictable low latency, and network-design flexibility. The architect compares the two: MetroCluster FC: dedicated Fibre Channel fabrics, lower and more deterministic latency MetroCluster IP: standard Ethernet/IP switches, simplified infrastructure and flexibility Concerns include a network team preference for IP simplicity, a storage team preference for FC determinism, latency-sensitive applications, FC budget constraints, and long-distance latency. Which architecture is preferred for lower-latency environments? A. MetroCluster FC with dedicated Fibre Channel fabrics B. MetroCluster IP with shared Ethernet networks C. MetroCluster IP with an ONTAP Mediator added D. Either variant, since both use one transport Answer: A 7.During a non-disruptive controller upgrade of one HA pair in a MetroCluster, an engineer must decide how the mirrored data and the DR relationship are handled while the old controllers are swapped for new ones. Which condition must hold for the upgrade to remain non-disruptive and keep the configuration protected? A. Both controllers in the HA pair must be replaced at the same instant so the new pair boots together with matching NVRAM and interconnect state B. The mirror plexes must be split and left unsynchronized until the new controllers are fully in place C. The Mediator must be taken offline so it does not falsely trip an unplanned switchover mid-upgrade D. Mirrored aggregates stay in sync and the DR partner site stays healthy, so redundancy covers service while controllers are swapped in turn Answer: D 8.An engineer at an energy utility prepares to perform a negotiated switchback after a planned switchover and site maintenance. Before issuing switchback, the engineer wants to confirm the environment is in a state that will allow the operation to succeed. Which two conditions must be satisfied before a negotiated switchback will proceed? (Choose two.) A. The data aggregates have been healed and are resynchronized between the sites B. The root aggregates have been healed so the recovered nodes can boot C. A SnapMirror baseline transfer has completed to the recovered site's volumes D. The ISL must be intentionally disabled during the switchback window to prevent conflicts E. All mirrored aggregates must first be converted to unmirrored to speed the operation Answer: AB 4 / 5 9.Which two components are required when setting up an IP-based MetroCluster configuration? (Choose two.) A. ATTO FibreBridge B. IP switches with proper redundancy C. SnapMirror software D. ONTAP Mediator Answer: BD 10.A pharmaceutical company's operations team reports intermittent performance drops on a MetroCluster IP system. Investigation shows the inter-switch link between the two sites is repeatedly going down and coming back up over short intervals — a flapping ISL — while the nodes themselves remain up and the Mediator stays reachable. What is the most likely consequence of a flapping ISL on the MetroCluster, and the correct focus for remediation? A. The Mediator will immediately force an unplanned switchover to the surviving site each time the inter- site link briefly drops, fencing off the partner to preserve a single active copy of the data B. Root aggregates automatically heal on each flap, so no back-end fabric action is required to restore redundancy C. Mirror writes between sites keep breaking, cycling aggregates through degraded/resyncing; remediation targets the fabric path — optics, cabling, switch ports — of the ISL D. The cluster peer relationship compensates by transparently rerouting the synchronous mirror traffic over the management network, so the flapping link is effectively harmless Answer: C 11.A customer is using MetroClusterTiebreaker software with Observer mode set to true. Tiebreaker just confirmed a disaster at one site. Which two steps must you perform to recover the service? (Choose two.) A. Execute the metrocluster switchover-forced-on-disaster true command on the surviving site. B. Verify that the disaster site is down. C. Open a case with the NetApp Support Site before executing any command on the system. D. Execute the metrocluster configuration-settings -switchover true command on the disaster site. Answer: AB 12.An administrator is asked to do a nondisruptive system refresh, replacing all NetApp FAS8200 controllers and disk shelves with newer NetApp AFF A900 controllers and disk shelves. Which two actions should the administrator take to migrate the data onto the new nodes before retiring the old controllers? (Choose two.) A. Perform a volume move. B. Perform an aggregate relocate. C. Create a second DR group. D. Create a network failover group. Answer: AC 5 / 5 13.Before upgrading ONTAP in a MetroCluster, which pre-upgrade step is critical for success? A. Verifying the backup of critical configuration data B. Reducing the number of active storage volumes C. Disabling SyncMirror temporarily D. Migrating all users to a different cluster Answer: A 14.A multinational enterprise operates a NetApp MetroCluster IP configuration across two sites (Site A and Site B) with athird site hosting the Mediator. The system is configured for automated switchover with: Mirrored aggregates Redundant IP switches Cluster peering configured Automated switchover enabled During a real incident simulation, the following sequence occurs: Network latency spikes beyond acceptable limits Mediator becomes temporarily unreachable Cluster interconnect shows intermittent packet loss One site experiences partial network isolation Switchover is attempted but fails Post-incident logs show: Mediator status: degraded/unreachable during event Intercluster LIFs flapping Aggregate mirroring temporarily suspended Healing operations delayed What is the most likely primary cause of switchover failure? A. Loss of quorum from Mediator unavailability B. Tiebreaker observer mode vetoing the switchover C. SnapMirror lag on the replicated volumes D. Intercluster LIFs placed on shared data ports Answer: A 15.In the event of a MetroCluster replication failure, which two steps should be taken to troubleshoot? (Choose two.) A. Check the cluster interconnect status B. Validate RDB consistency C. Check SnapMirror schedules D. Disable the FC switches Answer: AB