Text Material Preview
D-PST-MN-A-24 Dell PowerStore Maintenance Achievement exam dumps questions are the best material for you to test all the related DELL EMC exam topics. By using the D-PST-MN-A-24 exam dumps questions and practicing your skills, you can increase your confidence and chances of passing the D-PST-MN- A-24 exam. Features of Dumpsinfo’s products Instant Download Free Update in 3 Months Money back guarantee PDF and Software 24/7 Customer Support Besides, Dumpsinfo also provides unlimited access. You can get all Dumpsinfo files at lowest price. Dell PowerStore Maintenance Achievement D-PST-MN-A-24 exam free dumps questions are available below for you to study. Full version: D-PST-MN-A-24 Exam Dumps Questions 1.From where can a data collection be initialized within Dell EMC PowerStore Manager? A. Appliance, node, and storage resource B. Cluster, appliance, and event log C. Cluster, appliance, and alerts D. Node, storage resource, and alerts Answer: C Explanation: A data collection in Dell EMC PowerStore Manager can be initiated from the cluster, appliance, and alerts sections within the PowerStore Manager user interface. This process is essential for gathering system logs and other information that can be used for troubleshooting or analysis. To initiate a data collection, follow these steps: Log into the PowerStore Manager user interface. 1 / 7 https://www.dumpsinfo.com/unlimited-access/ https://www.dumpsinfo.com/exam/d-pst-mn-a-24 Navigate to the ‘Settings’ menu. Go to the ‘Support’ section. Select ‘Gather Support Materials’. Choose the scope of the data collection, which can be at the cluster level, for a specific appliance, or related to certain alerts. Click the ‘Gather Support Materials’ button to start the collection process. Monitor the progress in the ‘Jobs’ section of PowerStore Manager or within the ‘Support Materials’ section1. It is important to note that the data collection process may take some time to complete, depending on the amount of data and the system’s performance. Once the data collection is finished, the gathered materials can be used by Dell EMC support for further analysis or can be reviewed by the storage administrator to address any issues1. For more detailed instructions on data collection, refer to the Dell EMC PowerStore documentation or the support knowledge base articles provided by Dell23. Following these guidelines ensures that the data is collected correctly and efficiently. 2.Under which condition does the Dell EMC PowerStore equipment in the rack require additional stability? A. Unstable humidity B. When shipping the system C. Low temperatures D. High temperatures Answer: B Explanation: When shipping the system, additional stability is necessary to ensure that the equipment remains secure and undamaged during transportation. Proper stabilization prevents any potential movement or impact that could harm the delicate components of the system. 3.DRAG DROP Correctly order the steps of the embedded module replacement procedure. Answer: 2 / 7 https://www.dumpsinfo.com/ Explanation: The correct order of steps for the embedded module replacement procedure is: Power down the node Push the orange tab to release the lever of the embedded module Label and disconnect all cables attached to the embedded module Remove the 4-port card from the old embedded module and install it into the new embedded module Align the embedded module with the empty slot and carefully push it into the slot The procedure for replacing an embedded module in a Dell PowerStore system is a critical task that should be performed with care. Here is a detailed explanation of each step: Power down the node: Ensure that the node is properly powered down to avoid any electrical hazards or data corruption. This step is crucial for the safety of both the technician and the system1. Push the orange tab to release the lever of the embedded module: Locate the orange tab on the embedded module and push it to release the lever. This action will unlock the module from its slot1. Label and disconnect all cables attached to the embedded module: Before removing the embedded module, label all cables for easy reconnection later. Then, carefully disconnect each cable to free the module1. Remove the 4-port card from the old embedded module and install it into the new embedded module: Transfer the 4-port card from the old module to the new one. Handle the card with care to avoid damage to the electronic components1. Align the embedded module with the empty slot and carefully push it into the slot: Carefully align the new embedded module with the guides in the empty slot and gently push it into place until it is securely seated1. After completing these steps, reconnect the cables as per the labels, and power up the node to verify the operation of the new embedded module. For detailed instructions and safety information, refer to the Dell PowerStore Installation and Service Guide2. It is important to follow these guidelines closely to ensure the replacement is performed correctly and the system operates smoothly after the procedure. 4.How is a service laptop IP configured to connect to the Service LAN port of a Dell EMC PowerStore node? A. Static IP: 169.254.1.249 and netmask: 255.0.0.0 3 / 7 https://www.dumpsinfo.com/ B. Leave IP address and netmask unconfigured C. Static IP: 128.221.1.249 and netmask: 255.255.255.0 D. Obtain IP address from DHCP on PowerStore Answer: C Explanation: To connect a service laptop to the Service LAN port of a Dell EMC PowerStore node, the laptop’s Ethernet interface should be configured with a static IP address and netmask. The correct configuration is: IP: 128.221.1.249 Netmask: 255.255.255.0 Gateway: None1 This configuration allows the service laptop to communicate with the PowerStore nodes for SSH and PowerStore Manager (UI) access. It’s important to note that the laptop can be physically connected to one of the PowerStore nodes at a time, or to both nodes’ Service LAN ports using a small switch or hub. However, multiple appliances should never be connected to the same hub or switch as the nodes use the same internal IPs1. Once the IP is configured as shown above and the physical connection is established, you can ping the relevant IPs: Node A: 128.221.1.250 Node B: 128.221.1.251 You should only be able to ping the IPs where you are physically connected to. If you can ping, you can proceed to use SSH to connect to the IPs over port 22 using your preferred SSH client. For file transfers, SCP protocol must be used1. For more detailed instructions on how to connect to the system over the Service LAN Ports for SSH and PowerStore Manager access, refer to the Dell Support Knowledge Base Article1. 5.While on-site troubleshooting a Dell EMC PowerStore system, the node B embedded module fault LED is blinking blue and amber alternating at one second intervals. What does this indicate? A. Node is in service mode B. System is not initialized C. Node is booting D. Node is in degraded mode Answer: A Explanation: When the node B embedded module fault LED on a Dell EMC PowerStore system is blinking blue and amber alternating at one-second intervals, it indicates that the node is in service mode1. Service mode is a state where the node is not in normal operation and may be undergoing maintenance or diagnostics. In service mode, the node is typically isolated from normal storage operations to allow for troubleshooting, hardware replacement, or software updates without affecting the rest of the system. The alternating blue and amber LED is a visual indicator used by technicians to identify the current state of the node. To return the node to normal operation, the service task must be completed, and the node must be taken out of service mode using the appropriate commands through the system’s management interface. For detailed procedures on managing nodes in service mode, refer to the Dell EMC PowerStoreService Manual or contact Dell EMC Support for guidance2. 6.Refer to the exhibit. 4 / 7 https://www.dumpsinfo.com/ What Dell EMC PowerStore ToR front-end cabling is shown? A. VLT interconnectivity B. OOB Management C. Management and discovery D. Core switch uplink Answer: A Explanation: 7.What is the maximum number of base enclosures in a cluster when planning a Dell EMC PowerStore T installation? A. 3 B. 1 C. 4 D. 2 Answer: C Explanation: The maximum number of base enclosures in a cluster for a Dell EMC PowerStore T installation is 4. When planning the installation of a Dell EMC PowerStore T cluster, it is important to consider the scalability of the system. The PowerStore T series allows for clustering of multiple appliances to increase capacity and performance. According to the Dell PowerStore: Clustering and High Availability document, there is a minimum of one PowerStore appliance and a maximum of four PowerStore appliances that can be configured in the cluster1. This means that for a PowerStore T installation, you can start with a single appliance and scale up to a total of four appliances in a cluster as needed1. For detailed information on clustering and high availability features of the Dell EMC PowerStore T series, you can refer to the official Dell documentation1. 5 / 7 https://www.dumpsinfo.com/ 8.What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array? A. Stabilization Kit B. Rail Kit C. Maintenance Kit D. ESD Kit Answer: D Explanation: When replacing any components in a Dell EMC PowerStore array, it is critical to have an Electrostatic Discharge (ESD) Kit on hand to avoid equipment failure. The ESD Kit typically includes tools like wristbands and gloves that help prevent static electricity from damaging the electronic components during the replacement process. Before beginning any maintenance work on the PowerStore array, it is essential to: Use the ESD wristband by attaching one end to your wrist and connecting the other end to a grounded object. Wear ESD gloves to handle sensitive components. Ensure that the work area is free from static-prone materials and conditions. Follow the detailed safety precautions and procedures outlined in the PowerStore Installation and Service Guide1. Using an ESD Kit is a standard safety practice in the maintenance of electronic equipment, as static electricity can cause irreparable damage to sensitive components. The Dell PowerStore Installation and Service Guide provides comprehensive safety instructions, including the use of ESD protection, to ensure the safe handling of replaceable units2. 9.A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system. Which NDU software upgrade option is used for this situation? A. Drive firmware B. Hotfixes C. Software releases D. vCenter Answer: B Explanation: In the context of Dell EMC PowerStore, when a Storage Administrator needs to address specific fixes within their system, the appropriate Non-Disruptive Upgrade (NDU) software upgrade option to use is Hotfixes. Hotfixes are targeted software updates that address specific issues or bugs within the system without requiring a full software release upgrade1. The process for applying hotfixes typically involves: Identifying the specific issue and the corresponding hotfix that addresses it. Downloading the hotfix from the Dell Support website or through the PowerStore Manager interface. Applying the hotfix to the PowerStore system using the NDU process, which ensures that the system remains operational and accessible during the upgrade. Verifying that the hotfix has been applied successfully and that the issue has been resolved. It is important to follow the detailed instructions provided in the Dell PowerStore Software Upgrade Guide when applying hotfixes. This guide outlines the steps for preparing for an NDU, including any preliminary checks and concluding checks to ensure the integrity of the upgrade process2. Administrators should also consult the PowerStore Release Notes to determine which software upgrade packages, including hotfixes, are required for their specific PowerStore model and configuration2. Adhering to these guidelines helps ensure that the system is updated correctly and that the specific fixes are applied effectively. 6 / 7 https://www.dumpsinfo.com/ 10.The "svc_rescue_state list" shows a node in service mode. How can the node be returned to normal mode? A. svc_rescue_state quit B. svc_rescue_state clear C. svc_rescue_state normal D. svc_rescue_state exit Answer: B Explanation: To return a node from service mode to normal mode in a Dell EMC PowerStore system, the svc_rescue_state clear command should be used. This command clears the service mode state of the node and prepares it to return to normal operational mode1. Here are the steps to perform this action: Log in to the appliance from an SSH client. Run the svc_rescue_state clear command to clear the boot mode. Then, run the svc_node reboot command to reboot the node and return it to normal mode. After the reboot, you can verify that the node has returned to normal mode by running the svc_rescue_state list command again. It is important to follow these steps carefully to ensure that the node transitions back to normal mode without any issues. For more detailed instructions or if you encounter any problems during this process, refer to the Dell EMC PowerStore Service Scripts Guide or contact Dell EMC Support for assistance1. Powered by TCPDF (www.tcpdf.org) 7 / 7 https://www.dumpsinfo.com/ http://www.tcpdf.org